A fire fighting system controls and puts out a fire once it starts, protecting people, property and operations until the fire brigade arrives. In most buildings it is required for the fire NOC, and it works together with the fire detection and alarm system that gives the first warning.

Cyber Group designs, supplies, installs, tests and maintains fire fighting systems for factories, hospitals, hotels, commercial buildings, residential towers and campuses across India. With 25+ years in fire and ELV systems, we handle detection, fire fighting and suppression as one project.

Fire Fighting Systems We Install

  • Fire hydrant system: internal hydrants and landing valves, hose reels, yard hydrants and a fire brigade inlet, fed by fire pumps and a fire water tank. A reliable water supply for staff and firefighters to control larger fires.
  • Fire sprinkler system: wet, dry, pre-action and deluge systems that open automatically at the seat of the fire, reducing damage and saving lives.
  • Fire pumps: main electric pump, diesel standby pump and jockey pump, with controllers and pressure monitoring.
  • Water mist system: fine water mist for data centres, museums and other sensitive areas, using far less water than sprinklers.
  • Foam flooding system: foam for flammable liquid fires in chemical plants, fuel storage areas and refineries, helping prevent re-ignition.
  • Gas suppression system: clean agent or inert gas for server rooms, panel rooms and archives, where water would cause damage.
  • Fire extinguishers: portable ABC, CO2, water and foam extinguishers for immediate control of small fires.

Which System Fits Which Area?

SystemBest for
Fire hydrant and hose reelsEvery large building, plant and campus; used by staff and the fire brigade
Sprinkler systemOffices, hotels, hospitals, malls, warehouses and factories
Water mistData centres, museums and other sensitive, high-value areas
Foam floodingChemical plants, fuel storage areas and refineries
Gas suppressionServer rooms, UPS rooms, electrical panel rooms and archives
Fire extinguishersFirst response to small fires in every area

Most buildings need a combination of these. The final design depends on hazard class, building height and occupancy, and must follow NBC 2016 Part 4, IS 3844 / IS 13039 for hydrants, IS 15105 for sprinklers and your local fire authority.

Our Scope: Design to AMC

  1. Site survey and hazard study: occupancy, hazard class and water storage needs.
  2. Design and drawings: hydraulic calculations, pump sizing, pipe layout and drawings for fire NOC approval.
  3. Supply: certified products, compliant with RoHS, UL, CE, FCC and LPCB.
  4. Installation, testing and commissioning: pump room, piping, hydrants, sprinklers, valves, pressure and flow tests.
  5. Integration: pump and flow-switch status to the fire alarm system and the BMS.
  6. AMC and support: weekly pump runs, valve and gauge checks, hydrant and sprinkler inspections, extinguisher servicing and 24×7 support.

Fire Fighting Projects

  • Naxcure: sprinkler system and fire hydrant, together with door interlocking and time attendance.
  • Shayona: fire hydrant system, together with PA and networking.

Read our case studies on fire protection for Shifa Hospital, Bhuj, UltraTech Cement and Ajmera KalyanOne, Mumbai.

Industries We Protect

Factories and industrial plants · Hospitals · Hotels · Commercial complexes and IT parks · Residential towers · Warehouses · Chemical and pharma plants · Educational campuses · Data centres

Why Cyber Group

  • 25+ years of experience in ELV, fire and security systems
  • 3,000+ projects delivered across India
  • ISO 9001:2015 certified company
  • Detection, alarm, fire fighting and suppression from one team
  • AMC and 24×7 service support

Fire Fighting System: FAQs

What does a fire fighting system include?

A complete fire fighting system usually includes fire hydrants and hose reels, an automatic sprinkler system, fire pumps and a fire water tank, portable extinguishers, and special suppression such as gas, water mist or foam for high-risk rooms.

Which fire fighting system is required for my building?

It depends on the building type, height, area and occupancy. NBC 2016 Part 4 and your local fire authority set the requirements for the fire NOC. We design the system to meet them.

Which standards apply to hydrants and sprinklers in India?

Hydrant systems refer to IS 3844 and IS 13039, sprinkler systems to IS 15105, and all of them to Part 4 of the National Building Code 2016, along with local fire authority rules.

When should I use water mist or foam instead of sprinklers?

Water mist suits sensitive areas such as data centres and museums, where you want less water. Foam suits flammable liquid hazards such as fuel storage and chemical plants.

Do you provide AMC for fire fighting systems?

Yes. Our AMC covers pump runs, valve and gauge checks, hydrant and hose checks, sprinkler inspections and extinguisher servicing, with 24×7 service support.

Do you work outside Gujarat?

Yes. Our head office is in Ahmedabad and we deliver projects across India.

Need a Fire Fighting System for Your Building or Plant?

Talk to our team for a site survey, design and quote.

Your Queries, Our Priority – Contact Now!

From initial consultation to full-scale solutions, we’re committed to understanding your needs and delivering prompt, expert support

Get In Touch