False flooring, also called a raised access floor, is an elevated floor built on pedestals above the slab. The space below carries power cables, data cabling and, in many data centres, cold air for cooling. Cyber Group supplies and installs false flooring for data centres, server rooms, control rooms and offices, as part of our infrastructure solutions.

Benefits of raised access flooring

  • Neat routing of power and data cables
  • Easy access for maintenance and future changes
  • Underfloor air distribution for data centre cooling
  • Clean appearance with no surface cable trays
  • Flexible layouts when racks or desks move

Types of false floor panels

Panel typeTypical use
Steel cementitious-filledData centres and server rooms with high loads
Calcium sulphateOffices and control rooms needing low noise and rigidity
Perforated / grated panelsAirflow in front of racks in data centres
Anti-static finish (HPL/vinyl)Server rooms and electronics areas

What we plan in a false floor project

  1. Floor height based on cabling and cooling needs
  2. Load rating based on rack and equipment weight
  3. Panel type and finish
  4. Pedestals, stringers and earthing
  5. Cut-outs and grommets for cables and airflow
  6. Ramps and steps at entry points

Complete server room scope

False flooring works with water leakage detection, rodent repellent systems, structured cabling and gas suppression. We coordinate all of them in one design.

Why Cyber Group

  • 25+ years of experience in ELV, fire and security systems
  • 3,000+ projects delivered across India
  • ISO 9001:2015 certified company; certified products (RoHS, UL, CE, FCC, LPCB)
  • False floor coordinated with cabling, leak detection and fire protection
  • AMC and 24×7 service support

False Flooring Solutions: FAQs

What is false flooring?

False flooring is a raised floor installed on adjustable pedestals above the concrete slab, creating space below for cables and airflow.

What height is used for a data centre raised floor?

It depends on cabling and cooling design. Server rooms often use lower heights, while data centres with underfloor cooling need more height. We decide this during design.

Is false flooring anti-static?

Panels with anti-static finishes and proper earthing are used in server rooms and electronics areas.

Can you install leak detection under the raised floor?

Yes. Leak detection cable is commonly laid under raised floors near CRAC units and pipes.

Do you work outside Gujarat?

Yes. Our head office is in Ahmedabad and we deliver projects across India.

Plan your raised access floor

Share the room size, rack layout and cooling plan. We will suggest the floor system and send a proposal.

Your Queries, Our Priority – Contact Now!

From initial consultation to full-scale solutions, we’re committed to understanding your needs and delivering prompt, expert support

Get In Touch