A fire sprinkler system is one of the most reliable ways to control a fire in its early stage. It works automatically, day and night, without anyone pressing a button, and in many buildings in India it is required by the National Building Code and the local fire authority for the fire NOC.
Cyber Group designs, supplies, installs, tests and maintains fire sprinkler systems for offices, hotels, hospitals, malls, warehouses, factories and residential towers across India, together with the fire hydrant system, fire pumps and fire alarm system.
Types of Fire Sprinkler Systems We Install
| Type | How it works | Best for |
|---|---|---|
| Wet pipe | Pipes always full of water; heads open individually | Offices, hotels, hospitals, malls, most factories |
| Dry pipe | Pipes hold pressurised air; water enters when a head opens | Cold stores and areas where pipes may freeze |
| Pre-action | Water enters only after fire detection confirms a fire | Server rooms, archives, museums |
| Deluge | All nozzles open; water flows from every nozzle on detection | Transformer yards, fuel and chemical storage |
Key Parts of a Sprinkler System
- Water source: an underground or overhead fire water tank of the required capacity.
- Fire pumps: main electric pump, diesel standby pump and jockey pump to maintain pressure.
- Installation control valve (alarm valve): controls water into the system and raises the alarm with a water motor gong.
- Pipe network: risers, mains and branch pipes sized by hydraulic calculation.
- Sprinkler heads: pendent, upright, sidewall or concealed types, with temperature ratings to suit each area.
- Flow and tamper switches: report water flow and closed valves to the fire alarm panel and the BMS.
- Test and drain valves: for regular testing.
Standards We Follow
Automatic sprinkler systems in India are designed with reference to IS 15105 and Part 4 (Fire and Life Safety) of the National Building Code 2016, along with the local fire authority. Some global clients and insurers also follow NFPA 13. The hazard class of each area decides sprinkler spacing, water density and the water storage needed.
Our Scope: Design to AMC
- Hazard study: light, ordinary or high hazard classification for every area.
- Design and drawings: hydraulic calculations, pump and tank sizing, pipe layout and drawings for fire NOC approval.
- Coordination: with false ceilings, HVAC ducts and lighting so heads are not blocked.
- Supply: certified products, compliant with RoHS, UL, CE, FCC and LPCB.
- Installation, testing and commissioning: pipework, heads, valves, pressure tests and flow tests.
- AMC: weekly pump runs, valve and gauge checks, periodic flow tests and 24×7 service support.
Sprinkler Projects
For Naxcure, our scope included the sprinkler system and fire hydrant, together with door interlocking and time attendance. Read our case study on turnkey fire safety at Ajmera KalyanOne, Mumbai.
Part of a Complete Fire Protection System
Sprinklers work best together with fire alarm and detection, hydrants and hose reels, extinguishers and, for special rooms, gas suppression. See our complete fire fighting systems and fire protection solutions.
Why Cyber Group
- 25+ years of experience in ELV, fire and security systems
- 3,000+ projects delivered across India
- ISO 9001:2015 certified company
- Sprinklers, hydrants, pumps and fire alarm from one team
- AMC and 24×7 service support
Fire Sprinkler System: FAQs
Each sprinkler head opens on its own when the heat at that head reaches its rated temperature. Water flows onto the fire, and the flow switch and alarm valve raise the alarm and start the fire pump. In most fires only one or a few heads open.
No. In wet, dry and pre-action systems each head opens individually. Only deluge systems discharge from all nozzles together, and they are used for special high-hazard areas.
Automatic sprinkler systems are designed with reference to IS 15105 and Part 4 of the National Building Code 2016, along with local fire authority requirements. Some clients and insurers also ask for NFPA 13.
No. Sprinkler heads react to heat, not smoke. They open only when the temperature at the head reaches its rating.
Fire pumps are usually run weekly, valves and gauges are checked regularly, and full system checks are done at least once a year, as per your AMC and fire authority requirements.
Yes. Our head office is in Ahmedabad and we deliver projects across India.